Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Radiol ; 168: 111110, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37788519

RESUMO

PURPOSE: To find the optimal imaging parameters for a photon-counting detector CT (PCD-CT) and to compare it to an energy-integrating detector CT (EID-CT) in terms of image quality and metal artefact severity using a metal-containing bovine knee specimen. METHODS: A bovine knee with a stainless-steel plate and screws was imaged in a whole-body research PCD-CT at 120 kV and 140 kV and in an EID dual-source CT (DSCT) at Sn150 kV and 80/Sn150 kV. PCD-CT virtual monoenergetic 72 and 150 keV images and EID-CT images processed with and without metal artefact reduction algorithms (iMAR) were compared. Four radiologists rated the visualisation of bony structures and metal artefact severity. The Friedman test and Wilcoxon signed-rank test with Bonferroni's correction were used. P-values of ≤ 0.0001 were considered statistically significant. Distributions of HU values of regions of interest (ROIs) in artefact-affected areas were analysed. RESULTS: PCD-CT 140 kV 150 keV images received the highest scores and were significantly better than EID-CT Sn150 kV images. PCD-CT 72 keV images were rated significantly lower than all the others. HU-value variation was larger in the 120 kV and the 72 keV images. The ROI analysis revealed no large difference between scanners regarding artefact severity. CONCLUSION: PCD-CT 140 kV 150 keV images of a metal-containing bovine knee specimen provided the best image quality. They were superior to, or as good as, the best EID-CT images; even without the presumed advantage of tin filter and metal artefact reduction algorithms. PCD-CT is a promising method for reducing metal artefacts.


Assuntos
Metais , Tomografia Computadorizada por Raios X , Humanos , Bovinos , Animais , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos
2.
Acta Radiol Open ; 11(3): 20584601221075799, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35295865

RESUMO

Background: CT is often used for fracture evaluation following knee trauma and to diagnose ACL injuries would also be valuable. Purpose: To investigate the diagnostic accuracy of dual energy CT (DECT) for detection of ACL tears in acute and subacute knee injuries. Material and Methods: Patients with suspected ACL injury were imaged with DECT and MRI. Clinically blinded DECT images were independently read twice by two radiologists. ACL was classified as normal or abnormal. Arthroscopy served as reference method. Sensitivity and positive predictive value (PPV) were calculated, and diagnostic performance between DECT and MRI was assessed. Results: 48 patients (26 M, 22 F, mean age 23 years, range 15-37 years) were imaged with a mean of 25 days following trauma. Of these, 21 patients underwent arthroscopy with a mean of 195 days after trauma. Arthroscopy revealed 19 ACL tears and 2 ACLs with no tear. The combined sensitivity was 76.3% (95% CI 66.8-85.9) and 86.8 (95% CI 71.9-95.6) for DECT and MRI, respectively. There was no statistically significant difference between these two methods (p = .223). The positive predictive value (PPV) was 93.5 (95% CI 84.3-98.2) and 91.7 (95% CI 77.5-98.3) for DECT and MRI, respectively. Conclusion: DECT has lower sensitivity to detect an ACL rupture than MRI, but the difference is not statistically significant. The PPV is high in both methods.

3.
Acta Radiol ; 61(6): 749-759, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31581782

RESUMO

BACKGROUND: Dual-energy computer tomography (DECT) can detect post-traumatic bone marrow lesions. Prospective studies of the knee with large numbers of participants and intra-observer agreement assessment are limited. PURPOSE: To investigate the diagnostic accuracy of DECT in detecting bone marrow lesions as well as estimating the bone marrow lesion volume in patients with suspected anterior cruciate ligament trauma with magnetic resonance imaging (MRI) as reference standard. MATERIAL AND METHODS: Forty-eight consecutive patients with suspected anterior cruciate ligament injury were imaged bilaterally with DECT within a mean of 25 days (range 4-55 days) following injury and MRI within seven days of DECT. Two readers analyzed DECT virtual non-calcium-blinded images. Consensus MRI was reference standard. Intra- and inter-observer agreement were determined using weighted kappa statistics. Sensitivity, specificity, and negative and positive predictive values were calculated. Bone marrow lesion volumes were measured; for comparison, intra-class correlation coefficient was used. RESULTS: The 48 patients (26 men, 22 women; mean age 23 years, age range 15-37 years) were imaged bilaterally yielding 52 knees with bone marrow lesions, of which 44 were in the femur and 41 were in the tibia. Intra- and inter-observer agreement to detect bone marrow lesions was moderate and fair to moderate (κ 0.54-0.66, 95% confidence interval [CI] 0.39-0.80 and 0.37-0.41, 95% CI 0.20-0.57) and overall sensitivity and specificity were 70.1% and 69.1%, respectively. Positive and negative predictive values were 72.9% and 66.1%, respectively. Bone marrow lesion volumes showed excellent intra- and inter-observer agreement (0.83-0.91, 95% CI 0.74-0.94 and 0.76-0.78, 95% CI 0.57-0.87). CONCLUSION: The diagnostic performance of DECT to detect bone marrow lesions in the subacutely injured knee was moderate with intra- and inter-observer agreement ranging from moderate to substantial and fair to moderate. Bone marrow lesion volume correlation was excellent.


Assuntos
Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Medula Óssea/diagnóstico por imagem , Medula Óssea/lesões , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/complicações , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Estudos Prospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
4.
Acta Radiol Open ; 8(11): 2058460119889871, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31832242

RESUMO

BACKGROUND: Digital resources in learning are increasingly available and offer new possibilities in education. Mobile learning devices (MLD) such as tablets provide easy and flexible access for users. PURPOSE: To investigate whether the introduction of MLDs in radiology education affected time spent on studies over a longer time frame and whether learning behavior and attitudes changed. MATERIAL AND METHODS: The radiology residents employed during 2015-2016 were invited to participate in this 12-month MLD intervention study. Results were evaluated using online questionnaires at six months (6 m) and 12 months (12 m). RESULTS: Thirty-one residents were included, of whom half were in the early stages of residency (<2 years). After the MLD introduction, most participants (91% [6 m] and 83% [12 m]) estimated increased time spent on studies. Of these, 32% stated "a lot more" at 6 m but only 8% at 12 m (P = 0.12). The MLDs showed positive effects on the experience of radiology studies, as a majority of participants stated better quality and effectiveness in their studies (100% [6 m]-92% [12 m]), that MLD facilitated access to educational materials to a high degree (83% [6 m]-75% [12 m]), and that studies had become better and more fun (96% [6 m]-100% [12 m]). CONCLUSION: The use of MLDs seems to facilitate learning effectively for radiologic residents. However, a larger scale study is required as a trend of decreasing figures in the longer term was seen, but our results did not show a significant reduction of time spent on radiology studies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA